Draft Hood
Draft hood notched
to t over sections
J-bolt & nut
attach to front
of hood
Draft hood
clean-out
covers
Attaching Draft Hoods
1.
Attach draft hoods to boiler sections after applying
boiler Hercules Grrip to top of boiler sections where
hoods and sections meet.
2.
Use J-bolts to attach front of draft hoods to slots in
section anges. See Figure 13.